Solutions

Detachment of tiles in floors

Solutions

Detachment of tiles in floors

Technical Support +30 2103633512 Mon - Fri: 9:00 - 17:00

POTENTIAL CAUSES OF THE PROBLEM

  • An absorbent substrate caused the adhesive to fail.
  • There was a faulty application or a complete lack of primer.
  • An incorrect choice of adhesive was made.
  • Moisture entered the substrate due to cracked grout.
  • The adhesive was applied under unsuitable conditions (temperature exceeding 35 °C).
  • The adhesive was left on the application surface for too long before laying the tiles.

Product Categories

SOLUTION

STEP 1 Remove any adhesive from beneath the tile and the application surface.
STEP 2 Thoroughly clean the substrate to eliminate loose particles and dust.
STEP 3 If local repairs are necessary, use REPIFIX WRM 550 for masonry or REPIFIX WRM 525 for floors.
STEP 4 Prime the application surface with the high-penetrating acrylic primer GLX 292 FLEX PRIM.
STEP 5 Apply the appropriate tile adhesive based on the application (wall or floor) and the type of tile.
STEP 6 Finish by applying porcelain grout with texture LUX GROUTECH FMF 160.

Products Used

Repairing Mortars REPIFIX FAST WRM 550
Fast setting repairing plaster
Repairing Mortars REPIFIX POWER WRM 525
High strength, fiber reinforced, repairing mortar R4
MICROCEMENT DECOR GLX 292 FLEX PRIM
High penetration micronized acrylic primer