Detachment of tiles in coated surface (MDF, wood, formica)

POTENTIAL CAUSES OF THE PROBLEM

a) Poor choice of welding material

b) Due to contractions-expansions or vibrations created cracks in the grout and from there moisture penetrated in the substrate

SOLUTION

  1. Control of detached tiles
  2. Removal of the adhesive beneath the plate and the surface of application
  3. Application of the ready to use organic acrylic adhesive VKW 142 ACRYL
  4. Apply the porcelain grout texture FMF 160

Products used: