POTENTIAL CAUSES OF THE PROBLEM

  • Application of poor-quality paint
  • Application of a single-layer paint
  • Possible hairline cracks in plaster
  • Application of paint under prohibitive weather conditions (high temperatures)
  • Incomplete substrate cleaning from loose oils or powders
  • Possible problem with plaster
  • Possible lack of grid on connecting elements (walls-beams)

Product Categories

SOLUTION

STEP 1 Disassemble the loose parts and clean the surface with a brush.
STEP 2 Fill in the necessary areas with STATUS 100% acrylic putty.
STEP 3 Applu STATUS DUR primer.
STEP 4 Apply two coats of STATUS ALL WEATHER.

Products Used

PAINTS STATUS DUR
Waterproofing solvent-based acrylic primer
Acrylic Paints / Tinted Bases STATUS ALL WEATHER
Elastomeric Waterproof Facade Paint