POTENTIAL CAUSES OF THE PROBLEM

  • Application of final coat plaster directly on AAC blocks.
  • Application was not made with the proper tools

Product Categories

SOLUTION

STEP 1 Clean thoroughly with a brush, the surface from dust and loose particles.
STEP 2 Start repairing the cracked surface with the fast-setting repairing mortar REPIFIX WRM 520.
STEP 3 Prime the surface with deep penetration primer, GLX 292 FLEX PRIM.
STEP 4 Apply the first layer of fiber-reinforced base coat, THC 410.
STEP 5 As long as THC 410 is still wet, firmly CLIMAPLUS fiberglass mesh (160 g/m²).
STEP 6 Then, apply a second layer of fiber-reinforced, base coat, THC 410, in order to completely cover the mesh.
STEP 7 Prime the surface of application with the colored acrylic primer GLX 494 PRIM.
STEP 8 Apply the organic acrylic-based top coating DEC 428, at the color tone of our selection from the CLIMAPLUS fan deck.
STEP 9 Apply the organic acrylic-based top coating DEC 428, at the color tone of our selection from the CLIMAPLUS fan deck.
STEP 10 ATTENTION: If the application is in a seaside area or an area with high moisture content, THRAKON suggests the application of our silicone system. In such a case, proceed to the following steps: a) Prime the surface with the colored silicone-based primer GLX 498 CLIMASIL PRIMER. b) Application of organic silicone-based top coating DEC 438, in the color tone of our selection from the CLIMAPLUS fan deck.

Products Used