POTENTIAL CAUSES OF THE PROBLEM
- An absorbent substrate caused the adhesive to fail.
- There was a faulty application or a complete lack of primer.
- An incorrect choice of adhesive was made.
- Moisture entered the substrate due to cracked grout.
- The adhesive was applied under unsuitable conditions (temperature exceeding 35 °C).
- The adhesive was left on the application surface for too long before laying the tiles.
Product Categories
SOLUTION
STEP 1
Remove any adhesive from beneath the tile and the application surface.
STEP 2
Thoroughly clean the substrate to eliminate loose particles and dust.
STEP 3
If local repairs are necessary, use REPIFIX WRM 550 for masonry or REPIFIX WRM 525 for floors.
STEP 4
Prime the application surface with the high-penetrating acrylic primer GLX 292 FLEX PRIM.
STEP 5
Apply the appropriate tile adhesive based on the application (wall or floor) and the type of tile.
STEP 6
Finish by applying porcelain grout with texture LUX GROUTECH FMF 160.