Solutions

Surface cracks (on final coat plaster)

Solutions

Surface cracks (on final coat plaster)

Technical Support +30 2103633512 Mon - Fri: 9:00 - 17:00

POTENTIAL CAUSES OF THE PROBLEM

  • Rapid maturation of the final coat plaster (high radiation before the plaster dries)
  • Large application thickness of the final coat of plaster

 

Product Categories

SOLUTION

STEP 1 Rub the surface and remove loose.
STEP 2 Good cleaning of the surface.
STEP 3 Application of cementitious putty REPIFIX TOP WRM 483.
STEP 4 Priming of the surface with high penetration acrylic primer GLX 292 FLEX PRIM or STATUS DUR.
STEP 5 Paint the surface with sealing elastomeric paint STATUS ALL WEATHER.

Products Used

MICROCEMENT DECOR GLX 292 FLEX PRIM
High penetration micronized acrylic primer
PAINTS STATUS DUR
Waterproofing solvent-based acrylic primer
Acrylic Paints / Tinted Bases STATUS ALL WEATHER
Elastomeric Waterproof Facade Paint